| Availability: | |
|---|---|
The Topchill TQ-DDC Series is a cutting-edge low-temperature water-cooled screw chiller designed to operate at an ultra-low evaporation temperature of -40℃, making it a top choice for industrial freezing and cooling needs. It combines high-efficiency screw compressors, premium heat exchangers, and intelligent controls to deliver consistent performance in demanding environments—from food processing to pharmaceutical cold storage.

Equipped with advanced screw compressors that boost cooling efficiency by 15-20% compared to traditional models, reducing long-term energy costs.
Paired with high-performance shell-and-tube condensers and evaporators, optimized for heat transfer to ensure rapid temperature reduction.
Integrates world-renowned electrical components (e.g., sensors, relays) to minimize failure rates and extend service life.
Offers cooling capacity from 14,200 to 2,036,600 Kcal/h (17-49 kW), catering to small-scale workshops and large industrial facilities alike.
Achieves outlet temperatures as low as -35℃, meeting strict low-temperature requirements for quick freezing, pharmaceutical storage, and industrial processes.
Features a microprocessor-based system with real-time monitoring of temperature, pressure, and current, enabling precise adjustments.
Includes multi-layer protections: high/low pressure protection, phase failure/reversal protection, motor overload protection, and anti-freeze protection to prevent equipment damage.
Undergoes rigorous factory testing (100+ hours of operation) to ensure low noise (≤75 dB[A]) and stable performance in harsh conditions (e.g., high humidity, dust).
Compact structure saves 20% installation space; pre-assembled and pre-tested for quick on-site setup, reducing labor costs.
Compatible with food processing, cold storage, pharmaceuticals, and industrial cooling, with flexible customization for special low-temperature needs.
The TQ-DDC Series includes five models (100DDC, 140DDC, 180DDC, 230DDC, 260DDC) with core specs tailored for low-temperature performance:
Refrigerant: R22 or R404A (model-dependent) for optimal low-temperature cooling.
Nominal Cooling Capacity: Ranges from 14.2×1000 Kcal/h (17 kW, 4.7 USRT) to 42.1×1000 Kcal/h (49 kW, 13.9 USRT) (tested at evaporator -30℃/-15℃, condenser 30℃/35℃).
Power Supply: 3Φ-380V/50Hz, with operating current from 28.9A (100DDC) to 82.6A (260DDC).
Heat Exchangers: Shell-and-tube design (max water-side pressure 1 MPa); condenser/evaporator inlet/outlet diameters 2"-3".
Refrigeration: 1 circuit per unit, refrigerant charge 18-46 kg; energy control (0,66,100% or 0,50,75,100%) for load matching.
| WATER COOLED SCREW CHILLER TECHNICAL PARAMETERS IN LOW TEMPERATURE | |||||||||||
| Outlet water temperature:-35℃ | |||||||||||
| Model | 100DDC | 140DDC | 180DDC | 230DDC | 260DDC | ||||||
| Refrigerant | R22 | R404A | R22 | R404A | R22 | R404A | R22 | R404A | R22 | R404A | |
| Nominal cooling capacity | X1000Kcal/h | 14.2 | 16.3 | 19.4 | 21.5 | 25.5 | 28.4 | 33.9 | 37 | 37.2 | 42.1 |
| KW | 17 | 19 | 23 | 25 | 30 | 33 | 39 | 43 | 43 | 49 | |
| USRT | 4.7 | 5.4 | 6.4 | 7.1 | 8.4 | 9.4 | 11.2 | 12.2 | 12.3 | 13.9 | |
| Input power | KW | 17.2 | 19.7 | 22.9 | 25.9 | 29.3 | 33.2 | 39 | 43.8 | 42.6 | 49.2 |
| Compressor input power X number of units (KW) | 17.2x1 | 19.7x1 | 22.9x1 | 25.9x1 | 29.3x1 | 33.2x1 | 39.0x1 | 43.3x1 | 42.6x1 | 49.2x1 | |
| Unit operating current [A] | 28.9 | 33 | 38.6 | 43.6 | 49.2 | 55.9 | 65.6 | 73.6 | 71.6 | 82.6 | |
| power supply | 3Φ -380V~50Hz | ||||||||||
| protective device | Reverse phase protection, phase loss protection, overcurrent protection, exhaust temperature protection, high and low pressure protection, low temperature protection, water flow protection | ||||||||||
| Refrigeration circuit | 1 | ||||||||||
| Energy control [%] | 0,66,100 | 0.50,75,100 | |||||||||
| Refrigerant charge [kg] | 18 | 25 | 32 | 42 | 46 | ||||||
| Condenser | Shell and tube heat exchanger | ||||||||||
| Maximum pressure on water side [MPa] | 1 | ||||||||||
| Condenser inlet and outlet diameter [inch] | 2" | 2–1/2" | 3" | 3" | 3" | ||||||
| Cooling water flow rate [m³/h] | 5.8 | 6.7 | 7.8 | 8.8 | 10.1 | 11.4 | 13.5 | 14.9 | 14.8 | 16.9 | |
| Condenser water pressure drop [kPa] | 35 | 40 | 39 | 46 | 45 | ||||||
| Evaporator | Shell and tube heat exchanger | ||||||||||
| Maximum pressure on water side [MPa] | 1 | ||||||||||
| Evaporator inlet and outlet diameter [inch] | 2" | 2–1/2" | 3" | 3" | 3" | ||||||
| 40% ethylene glycol solution flow rate [m³/h] | 3.6 | 4.2 | 5 | 5.5 | 6.6 | 7.3 | 8.7 | 9.5 | 9.6 | 10.8 | |
| Evaporator water pressure drop [kPa] | 27 | 34 | 39 | 49 | 71 | ||||||
| Operating noise dB [A] | 73.1 | 73.7 | 74.8 | 75 | 75 | ||||||
| Machine weight [kg] | 1100 | 1160 | 1340 | 1500 | 1670 | ||||||
| Operating weight [kg] | 1200 | 1270 | 1510 | 1680 | 1830 | ||||||
Note:
1. Nominal cooling capacity: evaporator inlet and outlet water temperature -30℃/–15℃, condenser inlet and outlet water temperature 30℃/35℃, fouling coefficient 0.088m2℃kw;
2. Frozen water solution temperature range:-35℃-25℃
3. Cooling water temperature range:15℃-40℃
Quick freezing of meat, seafood, and prepared foods: -35℃ outlet temperature preserves texture and nutrients by reducing freezing time by 30%.
Fresh-keeping for fruits/vegetables: Maintains stable low temperatures to slow ripening and prevent spoilage.
Large cold storage warehouses: Stores frozen goods (ice cream, frozen meat) and pharmaceuticals (vaccines, biologics) for 6+ months.
Cold chain facilities: Ensures temperature stability during cargo handling, reducing product waste.
Vaccine production: Meets GMP standards for ultra-low temperature processing and storage (2-8℃ or below).
Hospital blood banks: Maintains consistent temperatures to preserve blood products.
Plastic injection molding: Cools molds to improve product precision; chemical reactions: Controls low-temperature reactions to enhance product quality.
A: MOQ is 1 piece, suitable for both small businesses and large industrial orders.
A: 2-4 weeks from order confirmation. Customized models may take 1-2 weeks longer, with timely updates provided.
A: Orders >$10,000: 30% deposit upfront, 70% before shipment.
Orders ≤$10,000: 100% advance payment.
A: Yes. We offer custom evaporation temperatures, cooling capacities, and additional safety features (e.g., remote monitoring) based on project requirements.
A: Stop the unit → check ethylene glycol solution level (add if low) → inspect evaporator for frost buildup (defrost if needed) → contact support if the issue persists.